The method of discharging condensate should be carried out after the machine is shut down, there is no pressure in the oil and gas separation tank, it is fully cooled, and the condensed water is fully precipitated, such as before starting in the morning.
1.Open the air release valve to eliminate air pressure.
2. Unscrew the front plug of the ball valve at the bottom of the oil and gas separation tank.
3 Slowly open the ball valve to drain until oil flows out, and close the ball valve.
4 Screw on the front plug of the ball valve